Shawn Tierney commented on lesson Lesson 31: Backing Up Your Project 4 years, 8 months ago
Good morning Nghia,
In Lesson 22 I cover how to connect the PanelView Plus to SLC-500, MicroLogix, ControlLogix, and CompactLogix. controllers. If you have questions on that process, please feel free to leave them there,
Sincerely,
Shawn Tierney,
Instructor at The Automation School -
Shawn Tierney commented on lesson Lesson 31: Backing Up Your Project 4 years, 8 months ago
Good afternoon Nghia,
Since we don't cover the PanelView Standard in this lesson or course, please post your question to me over on my blog on the article or video you feel is the best match:
– PanelView Standard: https://theautomationblog.com/?s=panelview+standardSincerely,
Shawn Tierney,
Instructor at The Automation School -
Shawn Tierney commented on lesson Lesson 32: Final Lesson 4 years, 8 months ago
Thanks Brad! I'd love to see a picture of the system when you're done! Shawn
-
Shawn Tierney commented on lesson Lesson 32: Final Lesson 4 years, 8 months ago
Good afternoon Bradley,
Sounds like a great application!
Most would use the Display Tags under Global Connections to accomplish this.
– The Replace Display Number tag writes the current screen number to the assigned tag (to the PLC)
– And if the tag assigned to the Remote Display Number is a non-zero value, the PVPlus will go to the…[Read more] -
Shawn Tierney commented on lesson Lesson 12: Graphics 4 years, 8 months ago
Good morning Gary,
Thanks for your question. I searched a couple of my VMs and it looks like Rockwell does not include the Baggage program (for PLC-5 and SLC-500) in later versions of FTView.
That said, I can confirm I do include the SLC-500 version in the downloads found in Appendix…[Read more]
-
Shawn Tierney commented on lesson Lesson 09: Intro to View Studio 4 years, 8 months ago
Good morning Gary,
Thank you for your question. Converting .MER runtime files can be quite complicated, and I do cover this in Appendix D.
That said, here's a couple of quick notes for anyone with similar questions:
1) Not all .MER files can be edited / restored to a project: Old versions didn't support this at all, and later versions…[Read more]
-
Shawn Tierney commented on lesson Lesson 29: .MER Runtime Files 4 years, 8 months ago
Good morning Felipe,
I believe you misunderstood my last reply – if you go back to Lesson 10, at the 42 second mark you'll see under “Project Settings” where you can choose a PanelView Plus 7.
When you choose a PanelView Plus 7 you will get a second option to choose Standard or Enhanced, as can be seen in the below image:
Hope this…[Read more]
-
Shawn Tierney commented on lesson Lesson 29: .MER Runtime Files 4 years, 8 months ago
Good afternoon Felipe,
Thanks for the update.
This is something we discussed at the very beginning of the course – the PanelView Plus Compact and PanelView Plus 7 Standard both have limited functionality.
You'll need to open Project Settings and change the selection to PVPlus 7 standard. In never versions of View Studio it's actually a…[Read more]
-
Shawn Tierney commented on lesson Lesson 29: .MER Runtime Files 4 years, 8 months ago
Good morning Felipe,
Thanks for your question.
What error is the PVP7 giving you?
Did you change the version of the runtime to match your PVP7's version prior to downloading it? (see 0:55 in the lesson video)
Hope this helps,
Shawn Tierney
Instructor at The Automation School -
Shawn Tierney commented on lesson Lesson 10: Software First Look 4 years, 8 months ago
Thank you Caina for your feedback!
Shawn Tierney,
Instructor at The Automation School -
Shawn Tierney commented on lesson Lesson 32: Troubleshooting Control 4 years, 8 months ago
Good morning Alvaro,
Thanks for your question.
Yes, you'll have access to the free running clock (S:4) in all SLC-500 and MicroLogix controllers.
In Logix controllers you need to read (GSV) the SystemDateAndTime variable into a tag first.
Hope this helps,
Shawn Tierney,
Instructor at The Automation Schoo -
Shawn Tierney commented on lesson Lesson 22: Communications Setup 4 years, 9 months ago
TEST
-
Shawn Tierney commented on lesson Lesson 22: Communications Setup 4 years, 9 months ago
Good morning Daniel,
Thanks for your questions.
Question: Restoring and editing .MERs
Restoring and editing a .MER project is not always possible, and therefore it's not listed in the course description as it's not covered in this course.
Instead, what is covered is the importance of having a project archive file (.APA) if you need…[Read more]
-
Shawn Tierney has passed the Quiz 02 – During installation, what crucial piece of info is needed? quiz with score 1 4 years, 9 months ago
Quiz 02 – During installation, what crucial piece of info is needed? by Shawn Tierney -
Shawn Tierney has passed the Quiz 01 – Where do you download VMware Workstation? quiz with score 1 4 years, 9 months ago
Quiz 01 – Where do you download VMware Workstation? by Shawn Tierney -
Shawn Tierney commented on lesson Lesson 10: Project System Settings 4 years, 9 months ago
Good morning Maitrey,
Yes, you can add Users and assign them Security Codes in Runtime Security.
That said, while I don't cover security in this course I added “Appendix C” which should help get you started.
Sincerely,
Shawn Tierney,
Instructor at The Automation School -
Shawn Tierney completed the course PAC Basics Extended Edition 4 years, 9 months ago
-
Shawn Tierney completed the lesson Update: How To Get Demo Software 4 years, 9 months ago
Lesson
Update: How To Get Demo Software by Shawn Tierneyin PVP Basics
-
Shawn Tierney completed the lesson Appendix A: All Downloads (PAE) 4 years, 9 months ago
Lesson
Appendix A: All Downloads (PAE) by Shawn Tierneyin PAC Basics Extended Edition
-
Shawn Tierney completed the lesson Lesson 51: Importing PLC Programs (Digital Only) 4 years, 9 months ago
Lesson
Lesson 51: Importing PLC Programs (Digital Only) by Shawn Tierneyin PAC Basics Extended Edition
- Load More