Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 5 months ago
Shawn,
Thanks, and not sure, I will connect, check IP address and settings as you advised. -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 5 months ago
Shawn,
Additional Information, I noticed there is VA1769/A local adapter and think it is rerated to DeviceNet and wonder this could be the cause . -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 5 months ago
Hi Shawn,
After going online using FTV Linx, I assigned a short cut to 1769-l35E/A, created a Runtime/Target and downloaded it to the PVP7 Performance for testing.
The person on the field said we still having “No communication” error.
Not sure what to do next at this point, I would think by assigning to the available processor online would surely work. -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Shawn,
Thanks and sorry I did not make myself clear, 1734 AENTR Ethernet/IP adapter, was not in the “Add Device Selection list”
However, I went online today, browsed the network in FTV as you showed in a video of this lesson and created a shortcut for 1769-L35E/A .
Waiting for the right time to replace the PVP6 and test. -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Shawn,
ViewStudio Release Number 11.00.00, Patch pack 28, Build 230.
1734 AENTR Ethernet/IP adapter, I only see 1734 AENTR/B Ethernet/IP adapter -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Hi Shawn,
Thanks and basically I am having communication message after transferring an application to a PVP7 to replace a PVP6.
Went through device shortcuts, check Runtime communication setup , all look good as I can tell.
At this point I am not sure where the problem is, all this is being done through remote email support, PVP6 and PVP7 are…[Read more] -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Hi Shawn,
In the Communication Setup, when adding devices to the Runtime(target), do I need to add drivers for that device?
Some devices I want to add are not in the Add Device Selection list.
I think I can go online with the system and browse for these devices but still need EDS files.
Are the EDS files attached to the FTV application .MER file -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Hi Shawn,
I have a copy V03.MER which need pass word, cannot be restored on my pc. However, I can load and run it on to the PVP 6.
Is there a way to export the FactoryTalk Linx Communications configuration from the PVP 6 to usb?
Or do I need the PLC program to set up paths and devices used in this setup communication configurations in the…[Read more] -
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Shawn,
Thanks and I tried “blank” and without entering any password still did not work .
Pixel Resolutions are different, transferred to PVP7 and the screens are placed on top right corner.
Only other way I can think of is to go on site, download the converted application to PVP 7 and compare every screen.Wondering if compare future in…[Read more]
-
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Thank You Shawn,
I am facing a challenge:
A customer wants to upgrade from PVP 6 to PVP 7,
I received the current a runtime V03, it is password protected when I tried to restore runtime application.However, I have the runtime V02 and pretty sure there are differences, guess I am against a brick wall.
-
Nghia Tran commented on lesson Lesson 29: .MER Runtime Files 3 years, 6 months ago
Hi Shawn,
Can I connect directly to the panel view using USB AB cable and what driver I need to add?
Reason is my ethernet card in my pc is not working. -
Nghia Tran commented on lesson Lesson 22: Communications Setup 4 years ago
Shawn,
Much appreciated, very helpful and thanks for the extra explanations,
Thanks
-
Nghia Tran commented on lesson Lesson 22: Communications Setup 4 years ago
Hi Shawn,
I have SLC 5/03 with DH485 and RS232 would like to establish communication with PV Pus 6.
I am using USB-1747-CP3 to go online with the controller, no issues,
Can’t get connected to the PVP 6 through Factory View Studio.
Is there some type of communication adapter I should use? -
Nghia Tran commented on lesson Lesson 31: Backing Up Your Project 4 years ago
Hi Shawn and thanks,
I have SLC 5/03 with DH485 and RS232 would like to establish communication with PV Pus 6.
I am using USB-1747-CP3 to go online with the controller, no issues,
Can't get connected to the PVP 6 through Factory View Studio. -
Nghia Tran commented on lesson Lesson 31: Backing Up Your Project 4 years, 1 month ago
Shawn,
My next question is, how would the panel plus communicate to SLC 500.
Thanks,
Nghia
-
Nghia Tran commented on lesson Lesson 31: Backing Up Your Project 4 years, 1 month ago
I found a web page ” Importing Legacy PanelView Projects Into Talk View Studio” protested by you.
Thanks.
-
Nghia Tran commented on lesson Lesson 31: Backing Up Your Project 4 years, 1 month ago
Shawn,
I have a hot topic, the customer has a Panel View 550 frozen, I have the .PVA application and looking for advice on how to transfer it to the panel view.
Thanks,
Nghia
-
Nghia Tran commented on lesson Lesson 44: VFDs for Motor Control (Digital Only) 4 years, 3 months ago
Thank you!
-
Nghia Tran commented on lesson Lesson 44: VFDs for Motor Control (Digital Only) 4 years, 3 months ago
Hi Shawn,
I there any reason to organize routines in different folders?
It seems like routines in a folder cannot call routines in another folder. -
Nghia Tran commented on lesson Lesson 46: Control VFDs over Ethernet (Digital Only) 4 years, 3 months ago
Thanks, I contacted Rockwell and got it under control.